Please follow these directions for the following products to avoid leaks, clogs, and other issues. Failure to adhere to these practices may invalidate your warranty.

How to fill & cap your Singular pods

How to set up your Singular jig
Air Pod: Postless
Filling Instructions
Recommended Needle Size | Ideal Fill Temperature | Capping Time |
|---|---|---|
16-20ga | 90°F/32°C (thinner oils) – 135°F/57°C (thicker oils) | Let stand for 10 mins |
Keep your needle clean to avoid making a seal in the filling hole, this can cause oil overflow.

Insert a blunt tip 16 to 20 gauge needle into center filling hole.
Caution: Be aware of filling needle depth, touching the ceramic core may cause damage.
90°F/32°C (thinner oils) 135°F/57°C (thicker oils). The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

Oversaturation from hot filling, thin oils, and/or slow capping will cause flooding, clogging and leaking.

Do not overfill your devices! Fill to a maximum of .55mL, 1.05mL, 2.05mL, 3.05mL, 4.05mL or 5.05mL depending on your configuration. Overfilling may cause seal bulging and will force fluid through the atomizer.

Let the device stand for 10 minutes before capping to ensure full saturation.
Capping Instructions
Capping Time | Capping Method | Minimum capping force | Maximum capping force |
|---|---|---|---|
Let stand for 10 mins | By hand or arbor press | 11-19lbs (5-9kg) | 130lbs (59kg) |
Ensure you use the air postless mouthpiece when capping your pod.

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (not at an angle) using even pressure, until you hear a click.

You can seat the mouthpiece by hand, but a light-duty arbor press and jig are recommended. Do not use a hammer or mallet. Pressing at an angle can lead to damage, improper sealing, leakage, and cracking of the device.

If too much pressure is applied during capping, you can damage the device. Check the pressure carefully.

You cannot remove the mouthpiece once it’s fully seated without damaging the device or the mouthpiece.

Let your pod stand for a minimum of 24 hours before using. During this time, the oil is priming the atomizer.
Pro Pod: Ceramic
Filling Instructions
Recommended Needle Size | Ideal Fill Temperature | Capping Time |
|---|---|---|
16-20ga | 90°F/32°C (thinner oils) – 135°F/57°C (thicker oils) | 3 mins or less (depending on viscosity) |
Do not remove the silicone plug when filling.

Insert a blunt tip 16 to 20 gauge needle into one of the two filling holes on either side of the center airway.
Caution: Do not allow oil to enter the center airway, it is in between the filling holes.
90°F/32°C (thinner oils) 135°F/57°C (thicker oils). The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

Oversaturation from hot filling, thin oils, and/or slow capping will cause flooding, clogging and leaking.

Do not overfill your devices! Fill to a maximum of 0.5mL or 1.05mL depending on your configuration. Overfilling may cause seal bulging and will force fluid through the atomizer.

Cap within 3 minutes after filling. We recommend a shorter period of time for thinner oils. Immediately after filling, cap the device with the mouthpiece until it’s fully seated.
Capping Instructions
Capping Time | Capping Method | Minimum capping force | Maximum capping force |
|---|---|---|---|
3 mins or less | By hand or arbor press | 11-19lbs (5-9kg) | 130lbs (59kg) |
For higher volume pods, gently press down the longer mouthpieces to align before capping.

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (not at an angle) using even pressure, until you hear a click.

You can seat the mouthpiece by hand, but a light-duty arbor press and jig are recommended. Do not use a hammer or mallet. Pressing at an angle can lead to damage, improper sealing, leakage, and cracking of the device.

If too much pressure is applied during capping, you can damage the device. Check the pressure carefully.

You cannot remove the mouthpiece once it’s fully seated without damaging the device or the mouthpiece.

Let your devices stand for between 30 minutes to 12 hours before using. During this time, the oil is priming the atomizer. More viscous oils will require more time.
Classic Pod: Stainless
Filling Instructions
Recommended Needle Size | Ideal Fill Temperature | Capping Time |
|---|---|---|
16-20ga | 90°F/32°C (thinner oils) – 135°F/57°C (thicker oils) | 3 mins or less (depending on viscosity) |
Do not remove the silicone plug when filling.

Insert a blunt tip 16 to 20 gauge needle into one of the two filling holes on either side of the center airway.
Caution: Do not allow oil to enter the center airway, it is in between the filling holes.
90°F/32°C (thinner oils) 135°F/57°C (thicker oils). The ideal fill temperature will allow for filling and capping before the oil saturates the atomizer.

Oversaturation from hot filling, thin oils, and/or slow capping will cause flooding, clogging and leaking.

Do not overfill your devices! Fill to a maximum of .55mL, 1.05mL, 2.05mL, 3.05mL, 4.05mL or 5.05mL depending on your configuration. Overfilling may cause seal bulging and will force fluid through the atomizer.

Cap within 3 minutes after filling. We recommend a shorter period of time for thinner oils. Immediately after filling, cap the device with the mouthpiece until it’s fully seated.
Capping Instructions
Capping Time | Capping Method | Minimum capping force | Maximum capping force |
|---|---|---|---|
3 mins or less | By hand or arbor press | 11-19lbs (5-9kg) | 130lbs (59kg) |
For higher volume pods, gently press down the longer mouthpieces to align before capping.

Make sure the mouthpiece is properly aligned and straight. Press the mouthpiece down vertically (not at an angle) using even pressure, until you hear a click.

You can seat the mouthpiece by hand, but a light-duty arbor press and jig are recommended. Do not use a hammer or mallet. Pressing at an angle can lead to damage, improper sealing, leakage, and cracking of the device.

If too much pressure is applied during capping, you can damage the device. Check the pressure carefully.

You cannot remove the mouthpiece once it’s fully seated without damaging the device or the mouthpiece.

Let your devices stand for between 30 minutes to 12 hours before using. During this time, the oil is priming the atomizer. More viscous oils will require more time.




































